LER Line Protector Prevents bird excrement from fouling
and building up on the insulator and tie. Available to fit pin
and post type insulator and a wide range of conductor sizes.
U-V Resistant, Fire Retardant, Flame Resistant
Dielectric Strength: exeeding 72kV
Sizing: According to ANSI Standards
LER Three Piece Birdguard Offers a “safe place to
perch”. Installed on a typical 3 phase 4 wire single crossarm
structure with lowered neutral (RUS C1 type construction),
this product allows birds to safely perch on the arm without
causing an outage. Available to fit pin and post type, tie and
clamp top insulators.
U-V Resistant, Fire Retardant, Flame Resistant
Dielectric Strength: exeeding 72kV
Sizing: By ANSI class of insulator
LER Triangle Antiperch Prevents birds from landing on
the crossarm and going phase-to-phase or phase-to-ground. UL
rated schedule 40 PVC; supplied mounting hardware; no metal
hardware above the crossarm.
U-V Resistant base, Fire Retardant, Flame Resistant
Available to standard 3.5" crossarm, two triangle converage widths: (20.5",18.5")
LER "Swing Plate" Triangles Low cost and easily
installed using a shotgun stick from a bucket truck, or
climbing the pole. This product has no springs or other
moving parts to wear out. The swing plate swivels under
the crossarm and tightens to provide a snug fit.
U-V Resistant
Available to fit a wide variety of crossarm sizes.
LER Nest Not Prevent the accumulation of nesting material
on the cross arms. Outages and structure fires can be caused by
large birds nesting above insulators and conductors on the H-Frames.
U-V Resistant, Fire Retardant, Flame Resistant
LER Horizontal Birdguard is designed to be used when
the conductors are less than 5’ from the pole, or have less
than 5 feet separation between conductors. Assembled, this
product will provide a total of 120” pf protection (5’ from
the center of the insulator in each direction).
UL Listed, U-V Resistant, Fire Retardant, Flame Resistant
Dielectric Strength: exeeding 72kV
LER Double Glass Birdguard Installed on a typical 3
phase, 4 wire double crossarm structure (RUS C-9 construction),
this product is available to fit pin and post-type insulators,
tie and clamp types.
UL Listed, U-V Resistant, Fire Retardant, Flame Resistant
Dielectric Strength: exeeding 72kV
Sizing: by ANSI Class of insulator
LER Wood Pole Cap prevent birds from perching on top of
the pole and simultaneously contacting the energized overhead
conductor and the grounded hardware on the ridge pin support.
Available in two sizes: base diameter of 9.75” and base diameter of 5.25”